Stylus Pro5000
9. Remove "Tension spring,28.76" located back of the belt pulley unit at the
left side of the mechanism, and release the timing belt.
10. Remove "Timing belt" from the pulley unit, and remove "Tension
spring,2.44" for linear scale from the frame. (Refer to Figure4-37)
11. Remove the connector for paper width sensor on the carriage unit.
12. Release engagement between the carriage unit and timing belt.
CHECK POINT
When installing "Timing belt" to the carriage unit
again, match the inside surface of the belt, which
has no ditches, to "A" part in the figure 4-38.
Rev. B
"Tension Spring, 28.76"
"Frame, Main, Rear"
Figure 4-37. Tension spring, Timing Belt and Linear Scale Removal
Connector for paper
width sensor
"Timing Belt"
Figure 4-38. Carriage Unit Removal
Chapter4 Assembly and Disassembly
Belt Pulley
"Timing Belt"
"Tension Spring,
"Linear Scale"
2.44"
No ditches
"A" part
4-21