D-Link DWS-4026 User Manual page 156

Dws-4000 series unified wired & wireless access system
Table of Contents

Advertisement

D-Link Unified Access System
Field
Days
Hours
Minutes
Default Router Addresses
DNS Server Addresses
NetBIOS Name Server
Addresses
NetBIOS Node Type
Next Server Address
Domain Name
Bootfile
Add Options
Code
Ascii Value
Hex Value
IP Address Values
After you configure values for the DHCP address pool, click Submit to create the pool and apply the changes to the
system.
To delete a pool, select the pool from the Pool Name drop-down menu and click Delete.
Page 156
Managing the DHCP Server
Table 70: Pool Configuration Fields (Cont.)
Description
For a Specified Duration lease time, this field specifies the number of days for the
lease period. The default value is 1, and the valid range is 0-59.
For a Specified Duration lease time, this field specifies the number of hours for the
lease period. The default value is 1, and the valid range is 0-1439.
For a Specified Duration lease time, this field specifies the number of minutes for the
lease period. The default value is 1, and the valid range is 0-86399.
Specifies the list of default router IP addresses for the pool. You can specify up to eight
addresses in order of preference.
Specifies the list of DNS server IP addresses for the pool. You can specify up to eight
addresses in order of preference.
Specifies the list of NetBIOS name server IP addresses for the pool. You can specify
up to eight addresses in order of preference.
Specifies the NetBIOS node type for DHCP clients:
• p-node Peer-to-Peer: Uses point-to-point name queries to a name server.
• m-node Mixed: Uses broadcasts first, then uses queries the name server.
• h-node Hybrid: Uses queries the name server first, and then uses broadcasts.
Specifies the IP address of the next server in the client's boot process, such as a TFTP
server.
Specifies the domain name for a DHCP client. The domain name can be up to 255
characters in length.
Specifies the name of the default boot image for a DHCP client. The file name can be
up to 128 characters in length.
The rest of the fields on the page allow you to add and configure DHCP options. See
RFC 2132 for more information about DHCP options.
Specifies the DHCP option code. The valid range is 1-254.
Specifies an NVT ASCII character string.
Specifies dotted hexadecimal data. Each byte in hexadecimal character strings is 2
hexadecimal digits. Each byte can be separated by a colon or white space. A period
separates 2 bytes/4 hexadecimal digits.
Specifies the Option IP addresses.
Software User Manual
Document 34CSFP6XXUWS-SWUM100-D7
12/10/09

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dwl-8600apDws-4000 series

Table of Contents