Sensor Test (high capacity output stacker)
Select Sensor Test from OUTPUT BIN TESTS.
1.
Select Output Bin x (x=number of the output option to be tested).
2.
The following screen is displayed:
HC Bin x TP=OPpassThru=Open Full=Open NearFull=Open
TP—High-capacity top position sensor
•
passThru—High-capacity pass thru sensor
•
Full—High-capacity bin full sensor (lower part of dual sensor)
•
NearFull—High-capacity bin near full sensor (upper part of dual sensor)
•
Manually actuate each of the sensors of the high-capacity stacker, and the display by each sensor toggles
3.
from Open to Closed.
Press Back (
4.
Sensor Tests (5-bin mailbox)
Select Sensor Tests from OUTPUT BIN TESTS.
1.
Select Output Bin x (x=number of the output option to be tested).
2.
The following screen is displayed:
Output Bin x
P1=OP P2=OP L=NL
passThru—5-bin mailbox pass thru sensor shows Open or Closed
•
mailboxEmpty—5-bin mailbox empty sensor shows Normal for a normal level, NearFull for nearly full,
•
and Full for full.
Manually actuate each of the sensors of the 5-bin mailbox,. The pass thru sensor will indicate Open or
3.
Closed and the empty sensor (mailboxEmpty) indicates Normal, NearFull, or Full.
Press Back (
4.
Diverter Test
This test verifies the functioning of each of the 5-bin mailbox output media diverters. If more than one 5-bin
mailbox is installed, all installed diverters or tested.
To run the Diverter Test, select Diverter Test from the OUTPUT BIN TESTS. The test runs once and stops.
Service Manual
3-16
)
r Stop (
o
) to exit the test.
)
r Stop (
o
) to exit the test.