Controller Reported POST Error. Error Code: X
Description: The controller returned an error from its internal POST.
Action: Replace the controller.

Controller Restarted with a Signature of Zero

Description: ADU
use to get the data. NVRAM may not be present (unconfigured) or the signature present in NVRAM may
not match the signature on the controller.
Action: Run the server setup utility to configure the controller and NVRAM.

Disable Command Issued

Description: The issuing of the Accelerator Disable command has disabled posted-writes. This occurred
because of an operating system device driver.
Action: Restart the system. Run ACU
accelerator board.
Drive (Bay) X Firmware Needs Upgrading
Description: Firmware on this physical drive is below the latest recommended version.
Action: Update the drive to the latest firmware version
Drive (Bay) X has Insufficient Capacity for its Configuration
Description: Drive has insufficient capacity to be used in this logical drive configuration.
Action: Replace this drive with a larger capacity drive.
Drive (Bay) X has Invalid M&P Stamp
Description: Physical drive has invalid monitor and performance data.
Action: Run the server setup utility to properly initialize this drive.
Drive (Bay) X Has Loose Cable
Description: The array controller could not communicate with this drive at power-up. This drive has not
previously failed.
Action:
Be sure all cables are properly connected and working.
1.
Power down the system and attempt to reconnect data/power cable to the drive.
2.
Power up the system.
3.
If the problem persists, power down the system and replace the cable.
4.
If the problem persists, power down the system and replace the drive.
5.
("Array diagnostic
software" on page 76) did not find a valid configuration signature to
("Array Configuration
Utility" on page 70) to reinitialize the array
("Firmware
maintenance" on page 80).