1776-Slot X Drive Array - Shared SAS Port Connection Conflict Detected - Ports 1I,
1E: Storage connections detected on both shared internal and external ports.
...Controller selects internal port until connection is removed from one of the ports.
Audible Beeps: None
Action: For cable configuration information, refer to the controller documentation.
1776-Drive Array Reports Improper SCSI Port 1 Cabling
Audible Beeps: None
Possible Cause:
The integrated array enabler board failed.
The I/O board, drive backplane fan board, or drive backplane failed.
Action:
Replace the integrated array enabler board.
1.
Update the integrated Smart Array option to the latest firmware version
2.
page 80).
CAUTION:
board. If you believe the I/O board requires replacement, contact HP Technical Support
("Contacting
Reboot the server after replacing each item:
3.
Drive backplane fan board
a.
Drive backplane
b.
I/O board
c.
1777-Slot X Drive Array - Storage Enclosure Problem Detected (followed by one or
more of the following)
(followed by one or more of the following):
...SCSI Port Y: Cooling Fan Malfunction Detected
SCSI Port Y: Overheated Condition Detected
SCSI Port Y: Side-Panel must be Closed to Prevent Overheating
SCSI Port Y: Redundant Power Supply Malfunction Detected
SCSI Port Y: Wide SCSI Transfer Failed
SCSI Port Y: Interrupt Signal Inoperative
SCSI Port y: Unsupported ProLiant Storage System Detected
Audible Beeps: None
Possible Cause: Environment threshold was violated on the drive enclosure.
Action:
Check the cooling fan operation by placing a hand over the fan.
Be sure the internal plenum cooling fan in tower servers or storage systems is operational. If the fan
is not operating, check for obstructions and check all internal connections.
Replace the unit side panel if removed.
Only authorized technicians trained by HP should attempt to remove the I/O
HP" on page 173) before proceeding.
("Firmware
maintenance" on
Error messages 151

Advertisement

Table of Contents
loading

This manual is also suitable for:

ProliantProliant 100 series

Table of Contents