Integrated Raid; Integrated Mirror; Global Hot Spare; Hp 8 Internal Port Sas Hba (Sas Controller) - HP Integrity rx3600 Installation Manual

Hide thumbs Also See for Integrity rx3600:
Table of Contents

Advertisement

Integrated RAID

Use Integrated RAID (IR) where either storage capacity, redundancy, or both of a RAID configuration
are required. Two components of IR are:
Integrated Mirror (IM)

Global Hot Spare

Integrated Mirror

The advantage of an IM is there is always a mirrored copy of the data. An IM provides data
protection for the system boot volume to safeguard critical information such as the operating system
on servers and high performance workstations. An IM supports two simultaneous mirrored volumes,
making an array, providing fault-tolerant protection for critical data. Typically, one of these volumes
is the boot volume. If a disk in an IM fails, the hot swap capability enables the volume to be easily
restored by replacing the failed disk. The firmware then automatically re-mirrors to the replaced
disk.
Global Hot Spare
Each SAS controller can have one global hot spare disk available to automatically replace a failed
disk in the one or two IM volumes configured on the controller. The hot spare makes the IM array
more fault tolerant. Up to two IM volumes are supported per SAS controller plus the hot spare.

HP 8 Internal Port SAS HBA (SAS Controller)

The following information is provided to assist you in configuring the 8 Internal Port SAS HBA
controller during installation.
To flash firmware, use the MPTUTIL command. To configure and maintain the IR functionality of
the SAS controller on the HP Integrity server, use the drvdfg and cfggen EFI commands. If you
are scripting multiple devices, use thecfggencommand.

MPTUTIL Utility

The mptutil utility enables you to update the adapter flash memory with the EFI driver and HBA
firmware. New versions of these images are released periodically.
IMPORTANT:
a SAS device and the update fails, these files will not be accessible.
To update firmware, follow these steps:
1.
Insert the HP IPF Offline Diagnostics and Utilities CD in the drive and boot to the EFI Shell.
NOTE:
at:
http://www.hp.com
IMPORTANT:
in the drive to allow device mapping. The EFI utility and firmware image files are located in
the root directory or in a subdirectory on the CD.
2.
The CD drive displays in the list of mapped devices as fs0. To change to this device, enter
fs0:
shell> fs0:
fs0:\
50
Installing the System
Do not store the files in this package on a SAS device. If you store these files on
You can also download the firmware image file and update utility from the HP website
in the Driver Downloads section.
When you boot the EFI enabled systems, the CD containing the utility must be

Advertisement