Memory problems

General memory problems are occurring
Action:
Isolate and minimize the memory configuration. Use care when handling DIMMs
guidelines" on page 19).
Be sure the memory meets the server requirements and is installed as required by the server.
o
Some servers may require that memory banks be populated fully or that all memory within a
memory bank must be the same size, type, and speed. To determine if the memory is installed
properly, see the server documentation.
Check any server LEDs that correspond to memory slots.
o
If you are unsure which DIMM has failed, test each bank of DIMMs by removing all other
o
DIMMs. Then, isolate the failed DIMM by switching each DIMM in a bank with a known working
DIMM.
Remove any third-party memory.
o
To test the memory, run HP Insight Diagnostics (on page 75).
Server is out of memory
Action:
Be sure the memory is configured properly. Refer to the application documentation to determine the
1.
memory configuration requirements.
Be sure no operating system errors are indicated.
2.
Be sure a memory count error
3.
message displaying memory count during POST.
Memory count error exists
Possible Cause: The memory modules are not installed correctly.
Action:
Be sure the memory modules are supported by the server. See the server documentation.
1.
Be sure the memory modules have been installed correctly in a supported configuration. See the
2.
server documentation.
Be sure the memory modules are seated properly
3.
Be sure no operating system errors are indicated.
4.
Restart the server and check to see if the error message is still displayed.
5.
Run HP Insight Diagnostics (on page 75). Then, replace failed components as indicated.
6.
("Memory count error
exists" on page 48) did not occur. Refer to the
("DIMM handling
("DIMM handling
guidelines" on page 19).