Ilo Generated Nmi - HP ProLiant BL620c - G7 Server Troubleshooting Manual

Proliant g4/5/6 servers
Hide thumbs Also See for ProLiant BL620c - G7 Server:
Table of Contents

Advertisement

iLO Generated NMI

Audible Beeps: None
Possible Cause: The iLO controller generated an NMI.
Action: Check the iLO logs for details of the event.
Internal CPU Check - Processor
Audible Beeps: None
Possible Cause: A processor has experienced an internal error.
Action: Run Insight Diagnostics
as indicated, including processors and PPMs.
Invalid memory types were found on the same node. Please check DIMM
compatibility. - Some DIMMs may not be used
Description: Invalid or mixed memory types were detected during POST.
Action: Use only supported DIMM pairs when populating memory sockets. Refer to the applicable server
user guide memory requirements.
Invalid Password - System Halted!
Audible Beeps: None
Possible Cause: An invalid password was entered.
Action: Enter a valid password to access the system.
Invalid Password - System Restricted!
Audible Beeps: None
Possible Cause: A valid password that does not have permissions to access the system has been entered.
Action: Enter a valid password with the correct permissions.
Memory found on unpopulated Node. — Processor is required to be installed for
memory to be used.
Description: The system detects DIMMs, but is unable to use the DIMMs because a processor is not
installed in the corresponding socket.
Action: To use the installed DIMMs, install a processor in the corresponding socket.
("HP Insight
Diagnostics" on page 75) and replace any failed components
Error messages 119