HP ProLiant BL620c - G7 Server Troubleshooting Manual page 146

Proliant g4/5/6 servers
Hide thumbs Also See for ProLiant BL620c - G7 Server:
Table of Contents

Advertisement

Audible Beeps: None
Possible Cause: The system detects that the drives are still present during POST and that the user
previously requested the drives to be removed from the controller configuration information.
Action: Do one of the following:
If the drives will be removed at a later time, press F1 to continue ignoring the physical drives.
To cancel the remove request and add these physical and logical drives back to the controller, press
F2.
1743-Slot X Drive Array - Logical Drive Erase Operation in Progress...
...Drives being erased are temporarily offline.
Audible Beeps: None
Possible Cause: The drives being erased are offline.
Action: Do one of the following:
Wait for the erase process to complete before using the logical drive.
Abort the erase process using ACU
1744-Slot X Drive Array - Drive Erase Operation In Progress or Queued...
...The following disk drive(s) will be blank upon completion: (followed by a list of drives)
Audible Beeps: None
Possible Cause: A drive erase operation was previously initiated by the user and is in progress or is
scheduled for all drives in the list.
Action: None required
1745-Slot X Drive Array - Drive Erase Operation Completed...
...The following disk drive(s) have been erased and will remain offline until hot-replaced or re-enabled by the Array
Configuration Utility:
(followed by a list of drives)
Audible Beeps: None
Possible Cause: The drive erase operation was successfully completed, and the drives are being held in
an offline state to ensure that the drives remain blank until re-enabled by the user.
Action: Replace each drive in the list or re-enable each drive in the list using one of the following
methods:
Use the Array Configuration Utility (on page 70) (all drive types).
Perform hot-plug removal and reinstallation (hot-plug hard drives only).
1746-Slot X Drive Array - Unsupported Storage Connection Detected...
...SAS connection via expander is not supported on this controller model. Access to all storage has been disabled.
Upgrade controller or detach the expander based storage connections.
("Array Configuration
Utility" on page 70).
Error messages 146

Advertisement

Table of Contents
loading

This manual is also suitable for:

ProliantProliant 100 series

Table of Contents