Fcfemoduledescr; Fcfemoduleobjectid; Fcfemoduleoperstatus; Fcfemodulelastchange - HP StorageWorks 2/64 - Core Switch Reference Manual

Hp storageworks fabric os 5.x mib reference guide (aa-rvhxb-te, september 2005)
Hide thumbs Also See for StorageWorks 2/64 - Core Switch:
Table of Contents

Advertisement

fcFeModuleDescr

OID
Description
Note

fcFeModuleObjectID

OID
Description
Note

fcFeModuleOperStatus

OID
Description

fcFeModuleLastChange

OID
Description

fcFeModuleFxPortCapacity

OID
Description
Note
1.3.6.1.2.1.75.1.1.4.1.2
A textual description of the module. This value should include the full name and version
identification of the module. It should contain printable ASCII characters.
See "sysDescr" on page 41.
1.3.6.1.2.1.75.1.1.4.1.3
The vendor's authoritative identification of the module. This value might be allocated
within the SMI enterprises subtree (1.3.6.1.4.1) and provides a straightforward and
unambiguous means for determining what kind of module is being managed.
For example, this object could take the value 1.3.6.1.4.1.99649.3.9 if vendor Neufe Inc.
was assigned the subtree 1.3.6.1.4.1.99649 and had assigned the identifier
1.3.6.1.4.1.99649.3.9 to its FeFiFo-16 PlugInCard.
See "sysObjectID" on page 41.
1.3.6.1.2.1.75.1.1.4.1.4
Indicates the operational status of the module:
• online (1): The module is functioning properly.
• offline (2): The module is not available.
• testing (3): The module is under testing.
• faulty (4): The module is defective in some way.
1.3.6.1.2.1.75.1.1.4.1.5
Contains the value of sysUpTime when the module entered its current operational status. A
value of 0 indicates that the operational status of the module has not changed since the
agent last restarted.
1.3.6.1.2.1.75.1.1.4.1.6
The number of Fx_Ports that can be contained within the module. Within each module,
the ports are uniquely numbered in the range from 1 to fcFeModuleFxPortCapacity,
inclusive. However, the numbers are not required to be contiguous.
The valid values are as follows:
• 8 for the SAN Switch 2/8-EL and SAN Switch 2/8V
• 12 for the Brocade 4Gb SAN Switch for HP p-Class BladeSystem
• 16 for the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/16, and SAN Switch
2/16V
• 32 for the SAN Switch 2/32 and SAN Switch 4/32
• 64 for the Core Switch 2/64
• 128 for the SAN Director 2/128
• 256 for the 4/256 SAN Director
Fabric OS 5.x MIB reference guide
75