swFault
This trap is no longer generated.
Trap #
OID
Enterprise
Variables
Description
swSensorScn
(Obsoleted by swFabricWatchTrap)
Trap #
OID
Enterprise
Variables
Description
swFCPortScn
Trap #
OID
Enterprise
Variables
1
1.3.6.1.4.1.1588.2.1.1.1.0.1
sw
swDiagResult,
swSsn
A swFault (1) is generated whenever the diagnostics detect a fault with the switch.
Sample Diagnostics:
#TYPE
#SUMMARY
#ARGUMENTS
#SEVERITY
#TIMEINDEX
#STATE
2
1.3.6.1.4.1.1588.2.1.1.1.0.2
sw
swSensorStatus, swSensorIndex, swSensorType, swSensorValue, swSensorInfo,
A swSensorScn (2) is generated whenever an environment sensor changes its operational
state: for instance, if a fan stops working. The VarBind in the Trap Data Unit contains the
corresponding instance of the sensor status, sensor index, sensor type, sensor value
(reading), and sensor information. Note that the sensor information contains the type of
sensor and its number, in textual format.
#TYPE
#SUMMARY
#ARGUMENTS
#SEVERITY
#TIMEINDEX
#STATE
3
1.3.6.1.4.1.1588.2.1.1.1.0.3
sw
swFCPortOpStatus, swFCPortIndex, swFCPortName,
Switch is faulty.
Faulty reason: %d and SSN is #%s
0, 1
Critical
1
Nonoperational
A sensor (temperature, fan, or other) changed its
operational state.
%s: is currently in state %d and SSN is #%s
4, 0, 5
Informational
1
Operational
swSsn
Fabric OS 5.x MIB reference guide 143
swSsn