Swfault; Swsensorscn; Swfcportscn - HP StorageWorks 2/64 - Core Switch Reference Manual

Hp storageworks fabric os 5.x mib reference guide (aa-rvhxb-te, september 2005)
Hide thumbs Also See for StorageWorks 2/64 - Core Switch:
Table of Contents

Advertisement

swFault

This trap is no longer generated.
Trap #
OID
Enterprise
Variables
Description

swSensorScn

(Obsoleted by swFabricWatchTrap)
Trap #
OID
Enterprise
Variables
Description

swFCPortScn

Trap #
OID
Enterprise
Variables
1
1.3.6.1.4.1.1588.2.1.1.1.0.1
sw
swDiagResult,
swSsn
A swFault (1) is generated whenever the diagnostics detect a fault with the switch.
Sample Diagnostics:
#TYPE
#SUMMARY
#ARGUMENTS
#SEVERITY
#TIMEINDEX
#STATE
2
1.3.6.1.4.1.1588.2.1.1.1.0.2
sw
swSensorStatus, swSensorIndex, swSensorType, swSensorValue, swSensorInfo,
A swSensorScn (2) is generated whenever an environment sensor changes its operational
state: for instance, if a fan stops working. The VarBind in the Trap Data Unit contains the
corresponding instance of the sensor status, sensor index, sensor type, sensor value
(reading), and sensor information. Note that the sensor information contains the type of
sensor and its number, in textual format.
#TYPE
#SUMMARY
#ARGUMENTS
#SEVERITY
#TIMEINDEX
#STATE
3
1.3.6.1.4.1.1588.2.1.1.1.0.3
sw
swFCPortOpStatus, swFCPortIndex, swFCPortName,
Switch is faulty.
Faulty reason: %d and SSN is #%s
0, 1
Critical
1
Nonoperational
A sensor (temperature, fan, or other) changed its
operational state.
%s: is currently in state %d and SSN is #%s
4, 0, 5
Informational
1
Operational
swSsn
Fabric OS 5.x MIB reference guide 143
swSsn

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks fabric os 5.x mib