Configuring Ntp Symmetric Peer Mode - 3Com 5500-EI PWR Install Manual

Hide thumbs Also See for 5500-EI PWR:
Table of Contents

Advertisement

[DeviceB] display ntp-service status
Clock status: synchronized
Clock stratum: 3
Reference clock ID: 1.0.1.11
Nominal frequency: 100.0000 Hz
Actual frequency: 100.0000 Hz
Clock precision: 2^18
Clock offset: 0.66 ms
Root delay: 27.47 ms
Root dispersion: 208.39 ms
Peer dispersion: 9.63 ms
Reference time: 17:03:32.022 UTC Apr 2 2007 (BF422AE4.05AEA86C)
The above output information indicates that Device B is synchronized to Device A, and the stratum level
of its clock is 3, one level lower than that of Device A.
# View the information about NTP sessions of Device B. (You can see that Device B establishes a
connection with Device A.)
[DeviceB] display ntp-service sessions
source
**************************************************************************
[12345]1.0.1.11
note:
1
source(master),2
associations :

Configuring NTP Symmetric Peer Mode

Network requirements
The local clock of Device A is set as the NTP master clock, with the clock stratum level of 2.
Device C (an S5500-EI Ethernet switch) uses Device A as the NTP server, and Device A works in
server mode automatically.
The local clock of Device B is set as the NTP master clock, with the clock stratum level of 1. Set
Device C as the peer of Device B.
Network diagram
Figure 1-7 Network diagram for NTP peer mode configuration
reference
stra reach poll
127.127.1.0
2
source(peer),3
1
now offset
1
64
1
350.1
selected,4
candidate,5
1-16
delay disper
15.1
0.0
configured
Total

Advertisement

Table of Contents
loading

This manual is also suitable for:

5500-ei series