3Com 5500-EI PWR Install Manual page 387

Hide thumbs Also See for 5500-EI PWR:
Table of Contents

Advertisement

Network diagram
Figure 4-7 Network diagram for PIM-DM configuration
Device
Interface
Switch A
Vlan-int100
Vlan-int103
Switch B
Vlan-int200
Vlan-int101
Switch C
Vlan-int200
Vlan-int102
Configuration procedure
1)
Configure the interface IP addresses and unicast routing protocol for each switch
Configure the IP address and subnet mask for each interface as per
steps are omitted here.
Configure the OSPF protocol for interoperation among the switches in the PIM-DM domain. Ensure the
network-layer interoperation among Switch A, Switch B, Switch C and Switch D in the PIM-DM domain
and enable dynamic update of routing information among the switches through a unicast routing
protocol. Detailed configuration steps are omitted here.
2)
Enable IP multicast routing, and enable PIM-DM on each interface
# Enable IP multicast routing on Switch A, enable PIM-DM on each interface, and enable IGMP on
VLAN-interface 100, which connects Switch A to the stub network.
<SwitchA> system-view
[SwitchA] multicast routing-enable
[SwitchA] interface vlan-interface 100
[SwitchA-Vlan-interface100] igmp enable
[SwitchA-Vlan-interface100] pim dm
[SwitchA-Vlan-interface100] quit
[SwitchA] interface vlan-interface 103
[SwitchA-Vlan-interface103] pim dm
IP address
Device
10.110.1.1/24
Switch D
192.168.1.1/24
10.110.2.1/24
192.168.2.1/24
10.110.2.2/24
192.168.3.1/24
20
Interface
IP address
Vlan-int300
10.110.5.1/24
Vlan-int103
192.168.1.2/24
Vlan-int101
192.168.2.2/24
Vlan-int102
192.168.3.2/24
Figure
4-7. Detailed configuration