Fc Fastwrite Concepts - HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual

Hp storageworks fabric os 6.x administrator guide (5697-0015, may 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Enable
Filter
Help
HEX
INDex xx
INOxid 0-FFFF
Lcontrol
N
NCfg
OUtoxid 0-FFFF
OXid 0-FFFF
P
PAGe n
PATh
Where:
Hd - Hd is the hex value for the Host Domain (the entry domain for this host port into the fabric)
Hp - is the hex value for the Host Port (the entry port of this host connection into the fabric)
Dd - is the hex value for the Device Domain (the entry domain for this device into the fabric)
Dp - is the hex value for the Device Port (the entry port for this device connection into the fabric)
Lp - is the Logical Partition (LPAR) value for the host accessing the specific device. This could also be
called CH or FICON Channel Number.
Cu - is the Control Unit number (CUADDR) for the specific FICON connection
Dv - is the Device Number of this FICON connected device.
POSt 0-100
RCtl 00-FF
RECords
RESet
Rsize
RXid 0-FFFF
SAVE n
SCfg
STATS
STATUs
T
TImestamp
TOken 0-FFFFFF
TRAcemask
TRIGGER
TRIGGERMask
TRIGGERS
TYpe

FC fastwrite concepts

FC fastwrite operates in Fibre Channel network topologies similar to the basic topology shown in
Figure
43. FC fastwrite provides accelerated speeds for SCSI Write operations over long distance Fibre
Enable traces for a tunnel.
Display the active trace filters.
Display this menu.
Display traces in HEX.
Display traces starting at index 'xx'.
Set/Reset the inbound FC OXID filter.
Set/Reset the FICON link control frame filter.
Display the next trace records.
Display a new FCTRACE configuration.
Set/Reset the outbound FC OXID filter.
Set/Reset the inbound and outbound FC OXID filters.
Display the previous trace record.
Set/Display the records per page to display.
Set/Reset the path filter HdHpDdDpChCuDv
Set/Display the post trigger percentage.
Set/Reset the FC R_CTL filter.
Specify/Display the number of records per buffer.
Reset all trace filters.
Specify the trace record size (80-240 bytes).
Set/Reset the FC frame RXID filter
Save trace buffer n for a tunnel to non-volatile memory.
Display the FTRACE configuration saved in persistent storage.
Display the FTRACE stats for a tunnel.
Set/Reset the FICON status frame filter.
Display the top (oldest) trace records.
Enable/Disable the timestamp display.
Set/Reset the FICON token filter.
Set/Display the trace mask (0-FFFFFFFF).
Display the first trigger point in the buffer.
Set/Display the trigger mask (0-FFFFFFFF).
Set/Reset the triggered event filter.
0-FF Set the FC frame TYPE frame filter.
Fabric OS 6.x administrator guide 457

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae370a - brocade 4gb san switch 4/12

Table of Contents