Disabling And Enabling Port Blades; Fr4-18I Blade Exceptions - HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual

Hp storageworks fabric os 6.x administrator guide (5697-0015, may 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

To power off a port blade:
Connect to the switch and log in as admin.
1.
2.
Enter the slotPowerOff command with the slot number of the port blade you want to power off.
switch:admin> slotpoweroff 3
Slot 3 is being powered off
switch:admin>
To provide power to a port blade:
1.
Connect to the switch and log in as admin.
2.
Enter the slotPowerOn command with the slot number of the port blade you want to power on.
switch:admin> slotpoweron 3
Powering on slot 3
switch:admin>

Disabling and enabling port blades

Port blades are enabled by default. In some cases, you will need to disable a port blade to perform
diagnostics. When diagnostics are executed manually (from the Fabric OS command line), many
commands require the port blade to be disabled. This ensures that diagnostic activity does not interfere
with normal fabric traffic.
To disable a port blade:
1.
Connect to the switch and log in as admin.
2.
Enter the bladeDisable command with the slot number of the port blade you want to disable.
switch:admin> bladedisable 3
Slot 3 is being disabled
To enable a port blade:
1.
Connect to the switch and log in as admin.
2.
Enter the bladeEnable command with the slot number of the port blade you want to enable.
switch:admin> bladeenable 3
Slot 3 is being enabled
FR4- 1 8i blade exceptions
You may wish to persistently disable FR4- 1 8i blade ports that are not configured so they cannot join the
fabric when the following scenarios apply:
The FR4- 1 8i blade ships with FOS 6.0.0b pre-installed. If this blade is inserted into a chassis running a
version of FOS that is different than the revision level currently on the blade, the blade firmware will be
upgraded or downgraded to match the firmware revision on the chassis.
You have inserted the FR4- 1 8i blade into a slot that was previously empty or contained an FC4-48,
FC4-32, FC8-48, FC8-32, FC4- 1 6, FC10-6, or FC4- 1 6IP.
You have turned on the power of the chassis and the FR4- 1 8i blade in that slot was not active prior to
the power-on.
If the FR4- 1 8i blade is operational and the Director is rebooted, then after the successful bootup of the
system the blade continues operations using the previous configurations.
If a previously configured FR4- 1 8i blade is removed and another or the same FR4- 1 8i blade is inserted into
the same slot, then the ports use the previous configuration and come up enabled.
If a previously-configured FR4- 1 8i blade is removed and an FC4-48, FC4-32, FC4- 1 6, FC8-48, FC8-32,
FC8- 1 6, or FC10-6 blade is plugged in, then—other than the port's EX_Port configuration—all the
remaining port configurations previously applied to the FR4- 1 8i FC_Ports can be used. The EX_Port
configuration on those ports is disabled before the FC4 or FC8 port blade becomes operational. When a
blade is present in the slot, then any requested port configuration is validated against the blade's
capabilities before accepting the request.