Daemons That Are Automatically Restarted - HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual

Hp storageworks fabric os 6.x administrator guide (5697-0015, may 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Schedule downtime and reboot the switch at your convenience.
considered non-critical and are automatically restarted on failure.
Table 6

Daemons that are automatically restarted

Daemon
Description
Asynchronous Response Router (used to send management data to hosts when the switch is accessed
Arrd
through the APIs (FA API or SMI-S).
Common Access Layer Daemon (used by Manageability Applications).
Cald
Event Monitor Daemon (used by port and switch SCNs, firmwareDownload, and configDownload)
Evmd
Remote Access Service Log Daemon logs error detection, reporting, handling, and presentation of
Raslogd
data into a format readable by management tools and the user.
Remote Procedure Call daemon used by the API (Fabric Access API and SMI-S).
Rpcd
Simple Network Management Protocol Daemon.
Snmpd
Trace Daemon. Provides trace entry date/time translation to Trace Device at startup and when
Traced
date/time changed by command. Maintains the trace dump trigger parameters in a Trace Device.
Performs the trace Background Dump, trace automatic FTP, and FTP "aliveness check" if auto-FTP is
enabled.
Track Changes Daemon.
Trackd
Webserver daemon used for Web Tools (includes httpd as well).
Webd
54
Standard features
Table 6
lists the daemons that are