6. Install the heat sink onto the microprocessor as described in "Installing a

Power supply

Complete the following steps to remove the non-hot-swap power supply.
Note:
Statement 5:
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current
from the device, ensure that all power cords are disconnected from the power
source.
1. Turn off the server and all attached peripheral devices.
2. Disconnect all power cords and external cables from the back of the server.
3. Remove the server from the rack; then, remove the server cover (see
4. Remove the power-cord module.
70
xSeries 335 Type 8676, Type 8830: Hardware Maintenance Manual and Troubleshooting Guide
Note: 0.01 mL is one tick mark on the syringe. If the grease is properly applied,
approximately half of the grease will remain in the syringe.
microprocessor" on page 52.
v Read "Installation guidelines" on page 37.
v Read the safety notices at "Safety information" on page 119.
v Read "Handling electrostatic discharge-sensitive devices" on page 122.
"Removing the cover and bezel" on page 44) and take out the air baffle.
Note: The illustrations in this publication might differ slightly from your
hardware.