Note: See "System" on page 112 to determine which components should be replaced by a field service technician.
Error code/symptom
184
(Power-on password damaged)
185
(Drive startup sequence information
corrupted)
186
(Security hardware control logic failed)
187
(VPD serial number not set.)
188
(Bad EEPROM CRC #2)
189
(An attempt was made to access the
server with invalid passwords)
196
(Microprocessor mismatch error)
201
(Memory test error.) If the server does not
have the latest level of BIOS installed,
update the BIOS to the latest level and run
the diagnostic program again.
229
(Cache error)
262
(DRAM parity configuration error)
289
(DIMM disabled by POST or user)
301
(Keyboard or keyboard controller error)
303
(Keyboard controller error)
602
(Invalid diskette boot record)
604
(Diskette drive error)
FRU/action
1. Run the Configuration/Setup Utility program.
2. System board.
1. Run the Configuration/Setup Utility program.
2. System board.
1. Run the Configuration/Setup Utility program.
2. System board.
1. Set serial number in the Configuration/Setup Utility program.
2. System board.
1. Run the Configuration/Setup Utility program.
2. System board.
v Run the Configuration/Setup Utility program, and enter the
administrator password.
1. Move microprocessor in socket 1 to socket 2, and move
microprocessor in socket 2 to socket 1.
2. Microprocessor.
1. DIMM
2. System board
1. Microprocessor
2. Optional microprocessor (if installed)
1. Run the Configuration/Setup Utility program.
2. Battery.
3. System board.
1. Run the Configuration/Setup Utility program, if the DIMM was
disabled by the user.
2. Disabled DIMM, if not disabled by user.
3. System board
1.
Keyboard
2. System board
v System board
1. Diskette
2. Diskette drive
3. Cable
4. System board
1. Run the Configuration/Setup Utility program and diagnostics.
2. Diskette drive.
3. Drive cable.
4. System board.
Chapter 6. Symptom-to-FRU index