15. Charging System/Battery

Service Information
Troubleshooting
Battery
Service Information
General Safety
The maintenance-free (MF) battery does not require battery acid level inspection. Do not replenish distilled
water.
To charge the battery, remove the battery from the frame, and charge it with its seal-cap closed.
Unless required in an emergency, do not carry out battery quick-charging.
Always charge battery based on the current and time specified on top of the battery.
Use a tester to check the charging status (open voltage).
Do not replace the battery with a general-type battery.
Check the charging system in sequence based on troubleshooting table.
Test-charging systems while they are mounted on the motorcycle.
For information on generator disassembly, refer to section 8.
Specifications
Battery
Generator
Regulator/rectifier
Tools
Measuring instruments
Digital circuit tester
PVA Multi-tester.
15-1
15-2
15-3
Item
Capacity
Terminal-to-terminal voltage (When fully charged)
Charging current
Leakage current
Charging coil resistance value (20 )
rpm at charging start
Type
Regulator voltage
Charging System/Battery
Charging System Inspection
Regulator/Rectifier
A.C generator Inspection
Standard values
Not to exceed 1mA
1,800rpm(night load)
14.5 0.5V/5.000/rpm
15-3
15-5
15-6
12V 8AH(MF)
13.0 13.2V
0.8A
0.1~1.0 (20 )
Thyristor system
15-1