Charging System/Battery - DAELIM NS125DLX Service Manual

Table of Contents

Advertisement

15. Charging System/Battery

Service Information
Troubleshooting
Battery
Service Information
General Safety
● The maintenance-free (MF) battery does not require battery acid level inspection. Do not replenish distilled
water.
● To charge the battery, remove the battery from the frame, and charge it with its seal-cap closed.
● Unless required in an emergency, do not carry out battery quick-charging.
● Always charge battery based on the current and time specified on top of the battery.
● Use a tester to check the charging status (open voltage).
● Do not replace the battery with a general-type battery.
● Check the charging system in sequence based on troubleshooting table.
● Test-charging systems while they are mounted on the motorcycle.
● For information on generator disassembly, refer to section 8.
Specifications
Battery
Generator
Regulator/rectifier
Tools
Measuring instruments
Digital circuit tester
PVA Multi-tester.
15-1
15-2
15-3
Item
Capacity
Terminal-to-terminal voltage (When fully charged)
Charging current
Leakage current
Charging coil resistance value (20℃)
rpm at charging start
Type
Regulator voltage
Charging System/Battery
Charging System Inspection
Regulator/Rectifier
A.C generator Inspection
Standard values
Not to exceed 1mA
1,600rpm(night load)
14.5±0.5V/5.000/rpm
15-3
15-5
15-6
12V–6AH(MF)
13.0–13.2V
0.9A
0.1~1.0Ω(20℃)
Thyristor system
15-1
15