Pulse Generator; Generator Inspection - DAELIM DAYSTAR Service Manual

Hide thumbs Also See for DAYSTAR:
Table of Contents

Advertisement

Performance Test
Measure it using the DAELIM PVA multi-
tester.
- PVA multi-tester
CAUTION
!
• Well read the instruction manual of tester and
handle it.

Pulse Generator

Disconnect the AC generator 3P coupler
blue/yellow wire connector.
Measure the resistance between green/white
and blue/yellow.
Standard: (Resistance)95-135
(Voltage) Over 0.7V
NOTE
• If the standard resistance is not obtained, check
all the related parts for the troubleshooting.
• Replacement of the pulse generator: refer to
section 7.
A.C Generator Inspection
Disconnect the AC generator coil wire
(black/red).
Measure the resistance between black/red and
ground.
Standard: 100-140
NOTE
• If standard resistance is not obtained, check all
the related parts for the troubleshooting.
(20 /68 )