Charging System/Battery
Regulator/Rectifier
Inspection of the harness circuit
Remove the left front side cover.
Disconnect the voltage regulator / rectifier
coupler.
Check for continuity between each terminal
and ground.
Inspection
Item
Continuity between red
Battery(Red)
Ground lead
Continuity between green
(Green)
and ground
Yellow-yellow standard
Charging coil
resistance, no continuity
lead(Yellow)
between yellow and ground.
Voltage detection When the main switch is
"ON" between black
lead(Black)
green
Regulator/Rectifier Inspection
If there is no problem in the starter inspection.
check the regulator/rectifier coupler. Measure
the resistance between the connector terminals.
CAUTION
!
• If the fingers reach to the metal part of tester
handle during the inspection, the resistance of
the human body is indicated. Therefore, be
careful of that
• Must inspect using the defined tester as the
below. If being inspected by different tester,
can not be inspected exactly because strange
resistance value is indicated.
• Measure the resistance using the DAELIM
PVA multi-tester.
- PVA multi-tester
16-6
Probe
and ground
, there is continuity.
and
PVA Adapter