In the Target line, yyyy-mm is the date when this target is activated, and identifier
is freely selectable. Find more about naming conventions in RFC 3722 (see
www.ietf.org/rfc/rfc3722.txt). Three different block devices are exported
in this example. The first one is a logical volume (see also
ration"
in the local file system. All these look like block devices to an iSCSI initiator.
Before activating the iSCSI target, add at least one IncomingUser after the Lun
definitions. It does the authentication for the use of this target.
To activate all your changes, restart the iscsitarget daemon with rciscsi restart.
Check your configuration in the /proc file system:
cat /proc/net/iet/volume
tid:1 name:iqn.2006-02.com.example.iserv:systems
There are many more options that control the behavior of the iSCSI target. Find them
in the manual page of ietd.conf.
Active sessions are also displayed in the /proc file system. For each connected initiator,
an extra entry is added to /proc/net/iet/session:
cat /proc/net/iet/session
tid:1 name:iqn.2006-02.com.example.iserv:system-v3
sid:562949957419520
initiator:iqn.2005-11.de.suse:cn=rome.example.com,01.9ff842f5645
sid:281474980708864 initiator:iqn.2006-02.de.suse:01.6f7259c88b70
12.1.3 Configuring Online Targets with
When changes to the iSCSI target configuration are necessary, you always must restart
the target to activate changes that are done in the configuration file. Unfortunately, all
active sessions are interrupted in this process. To maintain an undisturbed operation,
the changes should be done in the main configuration file /etc/ietd.conf, but
also made manually to the current configuration with the administration utility ietadm.
260
Installation and Administration
(page 111)), the second is an IDE partition, and the third is an image available
lun:0 state:0 iotype:fileio path:/dev/mapper/system-v3
lun:1 state:0 iotype:fileio path:/dev/hda4
lun:2 state:0 iotype:fileio path:/var/lib/xen/images/xen-1
cid:0 ip:192.168.178.42 state:active hd:none dd:none
cid:0 ip:192.168.178.72 state:active hd:none dd:none
ietadm
http://
Section 7.1, "LVM Configu-