14.6 SET BASIC ROTATION (Cycle
404, DIN/ISO: G404)
Cycle run
With Touch Probe Cycle 404, you can set any basic rotation
automatically during program run. This cycle is intended primarily for
resetting a previous basic rotation.
Cycle parameters
U
Preset value for basic rotation: Angular value
at which the basic rotation is to be set. Input
range -360.000 to 360.000
U
Number in table Q305: Enter the number in the
preset/datum table in which the TNC is to save the
defined basic rotation. Input range 0 to 2999
HEIDENHAIN iTNC 530
Example: NC blocks
5 TCH PROBE 404 BASIC ROTATION
Q307=+0
;PRESET BASIC ROTATION
Q305=1
;NO. IN TABLE
335