U
Measuring log Q281: Definition of whether the TNC is
to create a measuring log:
0: No measuring log
1: Generate measuring log: with the standard setting
the TNC saves the log file TCHPR424.TXT in the
directory in which your measuring program is also
stored.
2: Interrupt the program run and display the
measuring log on the screen. Resume program run
with NC Start.
U
PGM stop if tolerance error Q309: Definition of
whether in the event of a violation of tolerance limits
the TNC is to interrupt the program run and output an
error message:
0: Do not interrupt program run, no error message
1: Interrupt program run, output an error message
U
Tool number for monitoring Q330: Definition of
whether the TNC is to monitor the tool (see "Tool
monitoring" on page 400). Input range: 0 to 32767.9,
alternatively tool name with max. 16 characters:
0: Monitoring not active
>0: Tool number in the tool table TOOL.T
HEIDENHAIN iTNC 530
Example: NC blocks
5 TCH PROBE 424 MEAS. RECTAN. OUTS.
Q273=+50 ;CENTER IN 1ST AXIS
Q274=+50 ;CENTER IN 2ND AXIS
Q282=75
;FIRST SIDE LENGTH
Q283=35
;2ND SIDE LENGTH
Q261=-5
;MEASURING HEIGHT
Q320=0
;SETUP CLEARANCE
Q260=+20 ;CLEARANCE HEIGHT
Q301=0
;MOVE TO CLEARANCE
Q284=75.1 ;MAX. LIMIT 1ST SIDE
Q285=74.9 ;MIN. LIMIT 1ST SIDE
Q286=35
;MAX. LIMIT 2ND SIDE
Q287=34.95 ;MIN. LIMIT 2ND SIDE
Q279=0.1 ;TOLERANCE 1ST CENTER
Q280=0.1 ;TOLERANCE 2ND CENTER
Q281=1
;MEASURING LOG
Q309=0
;PGM STOP IF ERROR
Q330=
;TOOL