End angle B axis Q416 (absolute): Ending angle in the
B axis at which the last measurement is to be made.
Input range -359.999 to 359.999
U
Angle of incid. in B axis Q417: Angle of incidence
in the B axis at which the other rotary axes are to be
measured. Input range -359.999 to 359.999
U
Number meas. points B axis Q418: Number of probe
measurements with which the TNC is to measure the
B axis. If input value = 0, the TNC does not measure
the respective axis. Input range 0 to 12
U
Start angle C axis Q419 (absolute): Starting angle in
the C axis at which the first measurement is to be
made. Input range -359.999 to 359.999
U
End angle C axis Q420 (absolute): Ending angle in the
C axis at which the last measurement is to be made.
Input range -359.999 to 359.999
U
Angle of incid. in C axis Q421: Angle of incidence
in the C axis at which the other rotary axes are to be
measured. Input range -359.999 to 359.999
U
Number meas. points C axis Q422: Number of probe
measurements with which the TNC is to measure the
C axis. If input value = 0, the TNC does not measure
the respective axis. Input range 0 to 12
U
No. of measuring points (4/3) Q423: Specify
whether the TNC should measure the calibration
sphere in the plane with 4 or 3 probing points. 3
probing points increase the measuring speed:
4: Use 4 measuring points (standard setting)
3: Use 3 measuring points
U
Backlash, angle range Q432: Here you define the
angle value to be used as traverse for the
measurement of the rotary axis. The traversing angle
must be significantly larger than the actual backlash
of the rotary axes. If input value = 0, the TNC does not
measure the backlash. Input range: -3.0000 to
+3.0000