Example: Adjusting A Tool Changer Head - HEIDENHAIN ITNC 530 - CYCLE PROGRAMMING User Manual

Cycle programming
Table of Contents

Advertisement

U
Insert the second tool changer head.
U
Insert the touch probe.
U
Measure the head with Cycle 452.
U
Measure only the axes that have actually been changed (in this
example: only the A axis; the C axis is hidden with Q422).
U
The preset and the position of the calibration sphere must not be
changed during the complete process.
U
All other tool changer heads can be adjusted in the same way.
The head change function can vary depending on the
individual machine tool. Refer to your machine manual.
488

Example: Adjusting a tool changer head

3 TOOL CALL "TASTER" Z
4 TCH PROBE 452 PRESET COMPENSATION
Q407=12.5 ;SPHERE RADIUS
Q320=0
;SET-UP CLEARANCE
Q408=0
;RETR. HEIGHT
Q253=2000 ;F PRE-POSITIONING
Q380=45
;REFERENCE ANGLE
Q411=-90 ;START ANGLE A AXIS
Q412=+90 ;END ANGLE A AXIS
Q413=45
;INCID. ANGLE A AXIS
Q414=4
;MEAS. POINTS A AXIS
Q415=-90 ;START ANGLE B AXIS
Q416=+90 ;END ANGLE B AXIS
Q417=0
;INCID. ANGLE B AXIS
Q418=2
;MEAS. POINTS B AXIS
Q419=+90 ;START ANGLE C AXIS
Q420=+270 ;END ANGLE C AXIS
Q421=0
;INCID. ANGLE C AXIS
Q422=0
;MEAS. POINTS C AXIS
Q423=4
;NO. OF MEAS. POINTS
Q432=0
;BACKLASH, ANG. RANGE