HEIDENHAIN ITNC 530 - CYCLE PROGRAMMING User Manual page 386

Cycle programming
Table of Contents

Advertisement

U
Probe in TS axis Q381: Specify whether the TNC
should also set the datum in the touch probe axis:
0: Do not set datum in the touch probe axis
1: Set datum in the touch probe axis
U
Probe TS axis: Coord. 1st axis Q382 (absolute):
Coordinate of the probe point in the reference axis of
the working plane at which point the datum is to be
set in the touch probe axis. Only effective if Q381 = 1.
U
Probe TS axis: Coord. 2nd axis Q383 (absolute):
Coordinate of the probe point in the minor axis of the
working plane at which point the datum is to be set in
the touch probe axis. Only effective if Q381 = 1. Input
range –99999.9999 to 99999.9999
U
Probe TS axis: Coord. 3rd axis Q384 (absolute):
Coordinate of the probe point in the touch probe
axis, at which point the datum is to be set in the
touch probe axis. Only effective if Q381 = 1. Input
range –99999.9999 to 99999.9999
U
New datum in TS axis Q333 (absolute): Coordinate in
the touch probe axis at which the TNC should set the
datum. Default setting = 0. Input range: –99999.9999
to 99999.9999
386
Example: NC blocks
5 TCH PROBE 418 DATUM FROM 4 HOLES
Q268=+20 ;1ST CENTER IN 1ST AXIS
Q269=+25 ;1ST CENTER IN 2ND AXIS
Q270=+150 ;2ND CENTER IN 1ST AXIS
Q271=+25 ;2ND CENTER IN 2ND AXIS
Q316=+150 ;3RD CENTER IN 1ST AXIS
Q317=+85 ;3RD CENTER IN 2ND AXIS
Q318=+22 ;4TH CENTER IN 1ST AXIS
Q319=+80 ;4TH CENTER IN 2ND AXIS
Q261=-5
;MEASURING HEIGHT
Q260=+10 ;CLEARANCE HEIGHT
Q305=12
;NO. IN TABLE
Q331=+0
;DATUM
Q332=+0
;DATUM
Q303=+1
;MEAS. VALUE TRANSFER
Q381=1
;PROBE IN TS AXIS
Q382=+85 ;1ST CO. FOR TS AXIS
Q383=+50 ;2ND CO. FOR TS AXIS
Q384=+0
;3RD CO. FOR TS AXIS
Q333=+0
;DATUM
Touch Probe Cycles: Automatic Datum Setting