HEIDENHAIN ITNC 530 - CYCLE PROGRAMMING User Manual page 425

Cycle programming
Table of Contents

Advertisement

Cycle parameters
U
Starting point in 1st axis Q328 (absolute): Starting
point for probing in the reference axis of the working
plane. Input range -99999.9999 to 99999.9999
U
Starting point in 2nd axis Q329 (absolute): Starting
point for probing in the minor axis of the working
plane. Input range -99999.9999 to 99999.9999
U
Offset for 2nd measurement Q310 (incremental):
Distance by which the touch probe is displaced
before the second measurement. If you enter 0,
the TNC does not offset the touch probe. Input
range -99999.9999 to 99999.9999
U
Measuring axis Q272: Axis in the working plane in
which the measurement is to be made:
1:Reference axis = measuring axis
2:Minor axis = measuring axis
U
Measuring height in the touch probe axis
Q261 (absolute): Coordinate of the ball tip
center (= touch point) in the touch probe axis in
which the measurement is to be made. Input
range -99999.9999 to 99999.9999
U
Clearance height Q260 (absolute): Coordinate in the
touch probe axis at which no collision between touch
probe and workpiece (fixtures) can occur. Input range
-99999.9999 to 99999.9999, alternatively PREDEF
U
Nominal length Q311: Nominal value of the length to
be measured. Input range 0 to 99999.9999
U
Maximum dimension Q288: Maximum permissible
length. Input range 0 to 99999.9999
U
Minimum dimension Q289: Minimum permissible
length. Input range 0 to 99999.9999
HEIDENHAIN iTNC 530