HEIDENHAIN ITNC 530 - CYCLE PROGRAMMING User Manual page 391

Cycle programming
Table of Contents

Advertisement

2 TCH PROBE 413 DATUM OUTSIDE CIRCLE
Q321=+25 ;CENTER IN 1ST AXIS
Q322=+25 ;CENTER IN 2ND AXIS
Q262=30
;NOMINAL DIAMETER
Q325=+90 ;STARTING ANGLE
Q247=+45 ;STEPPING ANGLE
Q261=-5
;MEASURING HEIGHT
Q320=2
;SETUP CLEARANCE
Q260=+10 ;CLEARANCE HEIGHT
Q301=0
;MOVE TO CLEARANCE
Q305=0
;NO. IN TABLE
Q331=+0
;DATUM
Q332=+10 ;DATUM
Q303=+0
;MEAS. VALUE TRANSFER
Q381=1
;PROBE IN TS AXIS
Q382=+25 ;1ST CO. FOR TS AXIS
Q383=+25 ;2ND CO. FOR TS AXIS
Q384=+25 ;3RD CO. FOR TS AXIS
Q333=+0
;DATUM
Q423=4
;NO. OF MEAS. POINTS
Q365=1
;TYPE OF TRAVERSE
3 CALL PGM 35K47
4 END PGM CYC413 MM
HEIDENHAIN iTNC 530
Center of circle: X coordinate
Center of circle: Y coordinate
Circle diameter
Polar coordinate angle for 1st touch point
Stepping angle for calculating the starting points 2 to 4
Coordinate in the touch probe axis in which the measurement is
made
Safety clearance in addition to MP6140
Height in the touch probe axis at which the probe can traverse
without collision
Do not move to clearance height between measuring points
Set display
Set the display in X to 0
Set the display in Y to 10
Without function, since display is to be set
Also set datum in the touch probe axis
X coordinate of touch point
Y coordinate of touch point
Z coordinate of touch point
Set the display in Z to 0
Number of measuring points
Position on circular arc or linearly to the next touch point
Part program call
391

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Itnc 530Itnc 530 e