When installing the OAP card, note the following:
Make sure that the ejector levers are on the top of the OAP card. Then insert and push the OAP
card in the slot along the guide rails.
Do not touch the surface-mounted components directly with your hands.
Do not use excessive force while installing the OAP card. If you cannot insert the OAP card
smoothly, check whether the installation mode is correct.
Step5 Fasten the captive screws on the OAP card clockwise with the Philips screwdriver until the OAP card is
fixed into the chassis.

Removing an OAP Card

Step1 Wear an ESD-preventive wrist strap, ensure a good skin contact and make sure that the
ESD-preventive wrist strap is properly grounded.
Step2 Loosen the captive screws on the OAP card counterclockwise with the Philips screwdriver until all
spring pressure is released.
Step3 Hold each ejector lever with a hand and pull the ejector levers outward (see (4) in
pull out the OAP card slowly along the guide rails (see (3) in
Figure 3-44 Remove the OAP card
(1) OAP card
The protection panel on the OAP card surface has a yellow warning label
area corresponds to the inner heat radiator. After the OAP card runs for a period of time, this area may
be very hot. So keep your hands away from the area while removing the OAP card to avoid being hurt.
(2) Rear panel of the
switch
3-27
Figure
3-44).
(3) Pull-out direction of
the OAP card
Figure
3-44). Then
(4) Outward direction of
the ejector levers
, indicating that this