Appendix A Lightning Protection Of The Switch; Installation Of Lightning Arrester For Ac Power (Socket Strip With Lightning Protection - H3C S5800-32F Installation Manual

S5800 series ethernet switches
Hide thumbs Also See for H3C S5800-32F:
Table of Contents

Advertisement

Appendix A Lightning Protection of the Switch

Installation of Lightning Arrester for AC Power (Socket Strip with
Lightning Protection)
Lightning arrester will not be shipped with the switch. You should purchase it by yourself if needed.
If an outdoor AC power cord should be directly led to the switch, please serially connect the lightning
arrester for AC power (Socket Strip with Lightning Protection) before you plug AC power cord into the
switch, thus to prevent the possible damage to the switch due to lightning strike. You can use cable clips
and screws to fasten the lightning arrester for AC power on the cabinet, workbench or the wall of
equipment room.
Figure A-1 Diagram of lightning arrester
(1) Working LED (green)
(2) Grounding/pole detection LED
(red)
(3) Power switch
(4) IEC standard socket
(5) Overload automatic protector
(6) Multifunctional socket
On means the circuit is working normally; off means the
circuit is damaged.
On indicates a wrong wire connection (the wire is not
grounded or the live line and null line are reversely
connected), and you need to check the power supply line.
It is used to connect to the power supply in the equipment
room through a power cord.
It can reset automatically.
It is used to connect the power module of the device.
A-1