Installing an OAP Card
Installing an OAP Card to the Switch
Step1 Wear an ESD-preventive wrist strap, ensure a good skin contact and make sure that the
ESD-preventive wrist strap is properly grounded.
Step2 Loosen the captive screws on the filler panel with a Phillips screwdriver, as shown in
remove the filler panel from the slot to be used. Keep the removed filler panel properly for future use.
Figure 3-42 Remove the filler panel
(1) Rotation direction of the
Phillips screwdriver
Step3 Take the OAP card out of the package.
Step4 Push the OAP card slowly along the guide rails (see (3) in
inward to lock the OAP card in position (see (4) in
Figure 3-43 Install the OAP card to the switch
(1) OAP card
(2) Filler panel of the OAP card slot
(2) Rear panel of the
switch
3-26
Figure
3-43) and then push the ejector levers
Figure
3-43).
(3) Insertion direction of
the OAP card
Figure
3-42, and
(3) Phillips screwdriver
(4) Inward direction