Table 5 Error Codes - Freecom VALUELOADER DLT User Manual

Tape autoloader
Table of Contents

Advertisement

Table 5 Error Codes

Error Code
Description
3 0 81
Invalid Command Error.
3 0 82
Device Status Not Suitable To
Execute This Command.
3 0 83
Inventory Not Valid.
3 0 84
Source Empty.
3 0 85
Destination Full.
3 0 86
Import/Export Slot Access
Rejected.
3 0 87
Operation Timeout.
3 0 88
Communications Error
During Loop-back.
3 0 89
System Test Timeout.
ValueLoader DLT VS80/DLT VS160 Tape Autoloader User Manual
Diagnostics and Troubleshooting
Details
This error indicates that the ValueLoader
received an undefined command or an invalid
parameter with a command.
If the robotics are busy, some commands
cannot be executed at the same time. This error
indicates a probable violation. This is not an
error condition, but it does result in busy being
reported to the host for the requested SCSI
command.
The cartridge inventory is not valid because of
manual changes or previous fatal errors.
Update the inventory using the Re-inventory
option in the Configuration menu. See
an Inventory of Cartridges
cycle.
There is no cartridge in the location from which
a cartridge move was issued.
The location to which a cartridge move was
issued already contains a cartridge.
User attempted to access the Import/Export
slot, but media removal was prevented by the
host.
A command did not complete in the required
amount of time.
Cycle power on the ValueLoader and attempt
the operation again. If the error recurs, contact
Technical Support.
There was a communication timeout between
the drive and loader during the System Test.
ValueLoader Error Codes