Compaq 219700-001 - ProLiant - 1500 Reference Manual page 28

Array controller
Hide thumbs Also See for 219700-001 - ProLiant - 1500:
Table of Contents

Advertisement

2-10
Guidelines for Making Changes to Current Installation
Figure 2-5. Interim four-array state
ID6
ID5
ID4
ID3
ID2
ID1
ID0
Figure 2-6. Failed arrays removed; arrays on separate controllers
To restore an array to its original controller, make sure the conditions for
moving drives are met. Then:
IMPORTANT:
mistake could result in the loss of all data across all moved arrays.
1.
Power system OFF.
2. Move the array back to its original controller, but retain its drive
position as it was in the consolidated configuration.
3. Power system ON.
4. Each controller will indicate a 1789 POST message that drives are
missing. Press F2 to fail the missing drives.
5. Run Array Configuration Utility and remove the appropriate "failed"
arrays.
6. Reboot the system.
Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002
Controller 1
ID6
ID5
ID4
d
ID3
c
ID2
b
Array A
ID1
a
ID0
These steps must be followed EXACTLY. Any deviation or
File Name: C-CH02.DOC Last Saved On: 2/27/98 11:25 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
Controller 2
z
y
Array A
x

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents