Compaq 219700-001 - ProLiant - 1500 Reference Manual page 26

Array controller
Hide thumbs Also See for 219700-001 - ProLiant - 1500:
Table of Contents

Advertisement

2-8
Guidelines for Making Changes to Current Installation
3. Power system ON. A 1727 POST message should indicate that logical
drives were added to the configuration. If the system comes up with a
1785 (Not Configured) POST message, turn the system off
immediately to avoid data loss and return the drives to their original
locations.
NOTE:
channel controller, you may get an error message indicating a configuration
error. If you get this error message:
4. Run Array Configuration Utility to view the new drive configuration or
to assign spare drives (optional).
Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002
If you move arrays from a dual-channel controller to a single-
Return to the previous dual-channel controller configuration.
Back up data on the array.
Move the drives to the single-channel controller.
Run Array Configuration Utility on the single-channel controller to
configure the array.
Restore data to the array.
File Name: C-CH02.DOC Last Saved On: 2/27/98 11:25 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED

Hide quick links:

Advertisement

Table of Contents
loading