Compaq 219700-001 - ProLiant - 1500 Reference Manual page 180

Array controller
Hide thumbs Also See for 219700-001 - ProLiant - 1500:
Table of Contents

Advertisement

POST Error Messages
continued
1774
Slot x Drive Array - Obsolete data found in
Array Accelerator. Data found in accelerator
was older than data found on drives.
Obsolete data has been discarded.
(RESUME = F1 KEY)
1775
Slot x Drive Array - ProLiant Storage System
Not Responding SCSI Port (y): Check storage
system power switch and cables. Turn the
system power off while checking the
ProLiant power and cable connections, then
turn the system power back on to retry.
(RESUME = F1 KEY)
1776
Slot x Drive Array - SCSI Port (y) Termination
Problem Detected.
(RESUME = F1 KEY)
Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002
File Name: O-APPH.DOC Last Saved On: 2/27/98 12:10 PM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
Data found in Array Accelerator is older than
data found on drives due to drives having been
disconnected, used on another controller, and
then reconnected. Press F1 to discard older
data.
Turn off power to system. Check external
ProLiant power switch - external drives must
all be powered up before or at the same time
as the main system. Check cables. If retry does
not help, try replacing the cable, ProLiant
firmware, ProLiant backplane, or the SMART-2
Controller.
The termination power signal for the specified
SCSI port was shorted to ground. Termination
power was automatically turned off to prevent
damage to the internal hardware.
Turn off the server power and check the
cabling to the specified SCSI port. Replace
damaged cables/faulty SCSI devices attached
to cable.
SMART-2DH Array Controller Reference Guide
H-5
continued

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents