Compaq 219700-001 - ProLiant - 1500 Reference Manual page 175

Array controller
Hide thumbs Also See for 219700-001 - ProLiant - 1500:
Table of Contents

Advertisement

G-7
In cases of "legitimate" drive failure, once copies of important data have been
made (if possible), replace any drives that have failed to prevent further drive
problems in the future. After these (multiple) drives are replaced, the fault
tolerance may again be compromised, power may need to be cycled, and the
1779 POST message may again be displayed. Press F2 to reenable the logical
drive(s), recreate your partitions, and restore all data from backup.
Because of the risk that fault tolerance may be compromised at some point in
the future, make regular backups of all logical drives.
SMART-2DH Array Controller Reference Guide
Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002
File Name: N-APPG.DOC Last Saved On: 2/27/98 12:09 PM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED