Dell PowerEdge R410 Hardware Owner's Manual page 34

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge R410:
Table of Contents

Advertisement

Table 1-2. LCD Status Messages (Optional) (continued)
Code
Text
E2021
Incorrect
memory
configuration.
Review User
Guide.
E2022
General
failure
during POST.
Check screen
message.
E2023
BIOS Unable to
mirror memory.
Check DIMMs.
E2110
Multibit Error
on DIMM ##.
Reseat DIMM.
E2111
SBE log
disabled on
DIMM ##.
Reseat DIMM.
E2112
Memory spared
on DIMM ##.
Power cycle
AC.
34
About Your System
Causes
Incorrect memory
configuration.
General failure after video. Check screen for specific
The system BIOS could
not enable memory
mirroring because of a
faulty memory module or
an invalid memory
configuration.
The memory module in
slot "##" has had a
multi-bit error (MBE).
The system BIOS has
disabled memory
single-bit error (SBE)
logging and will not log
anymore SBEs until the
system is rebooted. "##"
represents the memory
module implicated by
the BIOS.
The system BIOS has
spared the memory
because it has determined
the memory had too many
errors. "##" represents the
memory module
implicated by the BIOS.
Corrective Actions
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 152.
error messages.
See "Troubleshooting
System Memory" on
page 152.
See "Troubleshooting
System Memory" on
page 152.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 152.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 152.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

External oemr r410

Table of Contents