3 Open the system. See "Opening the System" on page 82.
4 Disconnect the power and data cables from the back of the drive.
Note the routing of the power and data cables underneath the tabs on the
system chassis as you remove them from the system board and drive. You
must route these cables properly when you replace them to prevent them
from being pinched or crimped.
5 To remove the drive, pull the release latch and lift and angle the drive to
release it from the notch on the metal standoffs. Lift the drive out of the
chassis. See Figure 3-19.
6 Close the system. See "Closing the System" on page 83.
7 If applicable, replace the optional front bezel. See "Removing and
Replacing the Optional Front Bezel" on page 81.