Dell PowerEdge R410 Hardware Owner's Manual page 30

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge R410:
Table of Contents

Advertisement

Table 1-2. LCD Status Messages (Optional) (continued)
Code
Text
E1714
Unknown error.
Review & clear
SEL.
E171F
PCIe fatal
error on Bus
## Device ##
Function ##
E1810
Hard drive ##
fault. Review
& clear SEL.
E1812
Hard drive ##
removed. Check
drive.
E1920
iDRAC6 Upgrade
Failed.
E1A14
SAS cable A
failure. Check
connection.
30
About Your System
Causes
The system BIOS has
determined there has
been an error in the
system, but is unable to
determine its origin.
The system BIOS has
reported a PCIe fatal
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.
The specified hard drive
has experienced a fault.
The specified hard
drive has been removed
from the system.
optional iDRAC6
upgrade has failed.
SAS cable A is missing
or bad.
Corrective Actions
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help" on
page 167.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 159.
See "Troubleshooting a
Hard Drive" on page 156.
Information only.
See "Troubleshooting
Expansion Cards" on
page 159.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 167.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

External oemr r410

Table of Contents