Table 1-2. LCD Status Messages (Optional) (continued)
Code
Text
Causes
Corrective Actions
Ambient temperature has
See "Troubleshooting
E1114
Ambient Temp
a reached a point outside
System Cooling
exceeds
of the allowed range.
Problems" on page 151.
allowed range.
Memory has exceeded
Remove AC power to the
E1116
Memory
allowable temperature and
system for 10 seconds and
disabled, temp
has been disabled to
restart the system.
above range.
prevent damage to the
Power cycle
See "Troubleshooting
components.
AC.
System Cooling
Problems" on page 151.
If the problem persists,
see "Getting Help" on
page 167.
CMOS battery is missing
See "Troubleshooting the
E1210
Motherboard
or the voltage is outside of
System Battery" on
battery
the allowable range.
page 150.
failure. Check
battery.
RAID battery is either
Reseat the RAID battery
E1211
RAID
missing, bad, or unable to
connector. See "Installing
Controller
recharge due to thermal
the RAID Battery" on
battery
issues.
page 118, and
failure. Check
"Troubleshooting System
battery.
Cooling Problems" on
page 151.
3.3V voltage regulator has
Remove and reseat the
E1216
3.3V Regulator
failed.
PCIe expansion cards.
failure.
If the problem persists,
Reseat PCIe
see "Troubleshooting
cards.
Expansion Cards" on
page 159.
Specified processor
Reseat the processor(s).
E1229
CPU # VCORE
VCORE voltage regulator
See "Troubleshooting the
Regulator
has failed.
Microprocessors" on
failure.
page 160.
Reseat CPU.
If the problem persists,
see "Getting Help" on
page 167.