Ventilation / Installation Overview

The LST-4600A Integrator Box as well
as Plasma monitors generate heat dur-
ing operation and need to be provided
with adequate ventilation to assure con-
tinued reliable operation. See recom-
mendations below.
Ventilation Clearance
Proper clearance for air to flow
around the LST-4600A
Integrator Box must be provid-
ed.
Monitor Ventilation
Be sure proper ventilation is provided
for the monitor, see monitor installation
guide for specified ventilation require-
ments.
1. There are ventilation holes on three
sides of the the LST-4600A box pro-
vided for ventilation cooling.
a. If the box is mounted vertically,
the vents on the sides should be
located on the top and bottom
for free vertical air movement.
b. If the box is mounted horizontally,
the vents should be located at
the sides and top of the enclo-
sure (never mount the box with
vents facing down).
2. The vent holes should never be
blocked or obstructed to airflow but
have an unimpeded path through
any enclosure back to room temper-
ature air.
Vertical Installation (Wall Mount) Using
Supplied Angled L-Brackets
Two angled L-brackets are provided so that the
Integrator Box can be mounted on a flat vertical surface,
like a wall. Install the two angled L-brackets and the
screws provided.
Mount Integrator Box on the wall using four appropriate
screws.
ote
The brackets are designed to be mounted to typical 16"
spaced wall studs. Do not mount the Integrator Box to a
weak wall surface. If wall studs are not available, use
some other appropriate fastening system.
Monitor/Integrator Box Wall Mounting System
The plasma monitor and Integrator Box can be mounted
to a wall using an optional Monitor/Integrator Box wall
mounting system. For further information on the mount-
ing system, see your LG dealer.
Vent Holes
Vent Holes
Vent Holes
Vent Holes
Vent Holes
Ventilation Clearance
3. The unit and its venting, should
not be installed near heat sources
such as radiators or heating ducts.
4. If the unit is placed in an enclo-
sure, tests should be run to con-
firm that the ambient temperature
around the unit under normal
expected operating conditions is
stable and does not exceed 40
degrees Celsius (104F). This can
be determined by placing a ther-
mometer near the air intake vents
in the proposed enclosure and
measuring the temperature every
hour, under normal operating con-
ditions, until two successive read-
ings repeat. If temperature does
not stabilize but keeps increasing
Vent Holes
above 104F, ventilation is inade-
quate and needs to be improved.
5. Always provide adequate air space
between the ventilation areas and
adjacent structures.
Note
In addition to the ventilation require-
ments shown, be sure to allow enough
clearance (4" - 5") for wiring clusters
attached to the Integrator Box.
Proper clearance for air to flow around the
LST-4600A Integrator Box must be provided,
see above.