Detailed Descriptions of Installer Menu Items
0-I INSTALLER SEQUENCE
Gives access to Installer Menu depending on the code
selected.
0 = 9876
1 = 4321
2 = 1478
3 = 3698
1-I POWER MANAGE (Power Management)
Determines hours of no activity before automatic shut-
off. The POWER MANAGE function is for saving energy.
If set to 0, Power Manage is OFF. Settings range from 0
- 7, with 1 - 7 representing the hours that the Integrator
Box will remain on, unless there has been activity from
the Remote Control.
2-I AC ON (AC Power Switchable)
Allows the Integrator Box to turn ON just by applying AC
power. Pressing the ON button is not necessary. This is
desirable if the Integrator Box is plugged into a cable
box or a power outlet controlled by a wall switch. Use
ADJUST to select 0 or 1, where 0 is the default is OFF,
and 1 is ON.
NOTE: If set to 1 (ON), the Integrator Box does not
respond to ON/OFF commands from the Remote
Control, and the SLEEP TIMER is also nonfunctional.
3-I BAND/AFC (Band/Automatic Frequency Control)
There are 4 possible settings for this option:
0 = Broadcast
1 = CATV
2 = HRC
3 = IRC
NOTE: BAND is automatically set by AUTO PROGRAM.
the Integrator Box does not support AFC Search.
4-I STRT CHANNEL (Start Channel)
If active, this function allows you to determine the initial
channel number when the Integrator Box is turned ON.
This feature is useful for an in-house information chan-
nel, since the Integrator Box would always select that
channel when it is turned on. Setting this to 255 causes
the last channel viewed when Integrator Box was turned
off to be the tuned to channel when the Integrator Box
is turned on again.
255 = last channel
0 = AUX
5-I CHAN LOCK (Channel Lock)
If set to1, channel cannot be changed.
6-I GHOST CH. (Ghost Channel)
If set to 1, the current channel number is displayed in
the upper right corner of the monitor. The number
moves slightly to prevent damage to the screen. The
default is "0" or OFF.
NOTE: When captions are on, the "ghost channel" is not
displayed.
0-125 = ch
7-I STRT VOLUME (Start Volume)
This function allows the Installer to determine the initial
volume level setting when the Integrator Box is turned
ON. This feature is useful for an in-house information
channel, since the Integrator Box would always select
that volume level when it is turned on. The range of
values are 0 - 63, 255. If 255 is selected, the current
volume level will be retained in memory when the
Integrator Box is turned off; at Integrator Box turn on,
volume level is automatically set to the last level.
8-I MIN VOLUME (Minimum Volume)
This function determines the minimum volume level
allowable with the VOLUME (VOL) Up/Down control. In
this way, for example, someone cannot set the volume
too low to hear. The range is from 0 to 63—change val-
ues with ADJUST. The factory default is 0, which pro-
vides full range of volume control. It may be best to set
the same value on every Integrator Box.
NOTE: The minimum volume level cannot have a value
setting higher than in the MAX VOLUME level
(described below).
9-I MAX VOLUME (Maximum Volume)
This function determines the maximum volume level
allowable with the VOLUME VOL Up/Down control. In
this way, for example, someone cannot set the volume
level high enough to disturb others. The range is 0 to
63, with 63 as the default which gives the user the full
range of volume control. Change values with ADJUST
keys. It may be best to set the same value on every
Integrator Box.
NOTE: The maximum volume level cannot have a value
setting lower than the MIN VOLUME level (described
above).
10-I MUTE DISABLE
Enables or disables sound mute function. Set to 1,
sound cannot be muted. Set to 0, sound can be muted.
11-I NOT USED
12-I NOT USED
13-I NOT USED
14-I NOT USED
15-I SLEEP TIMER
If set to 1, the SLEEP TIMER feature may be used (but
no message is displayed prior to turn-off). If set to 0, the
sleep timer is not available.
16-I EN TIMER (Enables On-Off timers)
Set to 1, timer function is available to user. Set to 0 to
disable Timer functions. (Clock must be set in order to
use On/Off Timers.)
43