Adjusting Threshold Values

Threshold values are adjusted to determine the range for OK judgments.
Adjust the threshold values referring to the currently indicated measurement results. The
adjustment details differ according to the currently set teaching mode.
■ SEARCH, MATCH
●Switch to ADJ Mode.
Setting item
Correlation value
0 to 100
■ BRIGHT
●Switch to ADJ Mode.
●Adjustment of average density value
Upper/lower
limit
LEFT/RIGHT keys:Select upper limit/lower limit.
UP/DOWN keys: Change values.
Setting item
Average density value
0 to 255
Density deviation value
0 to 127
●Adjustment of correlation value
Measured value
Correlation value
UP/DOWN keys: Change values.
Range
This is the lower limit of the correlation value with the teaching model
This value or above is judged as OK.
Measured
value
Lower
Upper
limit
limit
Range
This is the range of the average density inside the teaching area.
This is the range of the density deviation inside the teaching area.

Adjusting Threshold Values

Details of Adjustment
●Adjustment of density deviation value
Lower
Upper
Upper/lower
limit
limit
limit
LEFT/RIGHT keys:Select upper limit/lower limit.
UP/DOWN keys: Change values.
Details of Adjustment
Section 3
Measured
value
ZFV
53
User's Manual