Setting Flowchart

4-2
Setting Flowchart
1
Set the I/O Slave Station.
2
Set the relay station.
3
Set the Serial Master Station
4
Check communications.
62
The settings required to perform communications using the relay function are
described using the following flowchart.
· I/O Slave Station settings
· Node number setting
· Frequency channel setting
· Relay station settings
· Node number setting
· Frequency channel setting
· Serial Master Station
settings
.
· Function setting switch
· Frequency channel setting
· I/O Slave Station, relay
station, Serial Master
Station settings
· MS and WS indicators lit
green.
· Node number setting
· Check RSSI display
The above example shows the procedure for setting the I/O Slave Stations,
followed by the Relay Station, and finally the Serial Master Station. When per-
forming communications, turn ON the power starting from the I/O Slave Sta-
tions in the same order as settings are made. Enable the relay function for the
I/O Slave Station to be used as a Relay Station by setting the corresponding
WT30 Terminal's node setting switch to 99. Set bit 3 of the Serial Master Sta-
tion's function setting switch to ON to enable detection of and communications
with the Relay Station.
Set the node number and frequency channel settings.
Set the node number to 99 to enable the I/O Slave Station to
function as a relay station.
Set the same frequency channel as other I/O Slave Stations.
Set the function setting switch to enable the relay function.
Set the same frequency channel as other I/O Slave Stations.
Set the node number to suit the application.
· Using Registered I/O Slave Stations
Enable the scan list at the Serial Master Station to enable
communications with the registered specified I/O Slave
Station.
· Using Unregistered I/O Slave Stations
Disable the scan list to enable communications with the
number of I/O Slave Stations set using the Serial Master
Station's node setting switch.
After completing all the settings, change the mode setting
switch to RUN mode.
Check whether communications are normal and check the
RSSI display and WS indicator on the Serial Master Station or
I/O Slave Stations.