Section 2 NS Series Functions
NS Series Programming Manual
Settings for Functional Object Properties
1.
Place a data log object on the screen if there isn't one there already.
2.
Double-click the data log object to display the General Tab Page for the functional object proper-
ties.
3.
Select the address from the data log address list, and double-click it, or click the Display Pa-
rameter Button at the top right of the screen to display the Display Parameter Settings Dialog
Box.
4.
Click the Set Button next to Line color to set the line color for the stored graph, to distinguish the
stored graph read from the Memory Card from the graph of data currently being logged. In this
example, No. 012 (red) is selected for the stored graph.
5.
Click the OK Button to return to the Functional Object Properties Dialog Box.
6.
Display the Time Axis Tab Page and set the graph time axis scale. In this example, "50" seconds'
worth of logging data will be displayed.
7.
Select Position end of scrolling at the center of data log graph when all of the standard data can-
not fit on to the graph.
3
If Step display is selected, the logged
points will be connected by vertical
and horizontal lines.
De-select Step display to join logging
points by the shortest possible straight
line.
Sets the line color when logging data
is read from the Memory Card and
displayed. In this example, No. 012
(red) has been selected.
2-361
2-15 Data Logs