Accessing Parameters

!WARNING
4-6
Accessing Parameters
4-6-1
Accessing General (AC Drive Profile) Objects
4-6-2
Accessing Inverter parameter using Function Code Object
26
Always clear the run bits FWD and REV in your PLC program on the rising
edge of the FLT bit. Not doing so may result in the motor starting unexpect-
edly when the trip is cleared via DeviceNet or the „Stop/reset" button on the
Inverter
DeviceNet
explicit
3G3AX-MX2-DRT-E Unit can be used to access any parameter from the Unit
or the MX2-A@ Inverter. Please refer to the APPENDIX E DeviceNet Explicit
Messages on page 71 for details and examples.
Refer to the DeviceNet Master Units Operation manual (Cat. No. W380) for
details on how to send the explicit messages to the 3G3AX-MX2-DRT-E.
Below are examples for usage of the OMRON CJ1W-DRM21 Master Unit with
the FINS Explicit Message Send command (2801).
Reading the value of MX2-A@ inverter input terminal [4].
Command:
28
Command Code
Destination node address
Response:
28
Command Code
The value of input terminal [4] is ON.
Writing the value of the acceleration time (F002) to 3.00 seconds (012C Hex).
The parameter F002 corresponds to address 5002 (138A Hex). Please note
the swapping of the data following CIP data type encoding.
Command:
28
01
Command Code
Destination node address
Response:
28
Command Code
messages
sent
from
01
0E
00
Class ID
Service Code
01
00
00
03
End Code
No. of bytes received
Source node address
10
00
65
00
Class ID
Instance ID
Service Code
02
01
00
00
End Code
No. of bytes received
Source node address
Section 4-6
the
Master
Unit
08
00
04
03
Instance ID
Attribute ID
8E
01
Data
Service code
13
8A
2C
01
Data
Attribute ID
90
Service code
to
the
00
00