Omron MX2 DEVICENET OPTION BOARD User Manual page 42

Mx2 devicenet option board
Table of Contents

Advertisement

Flexible Format
4-7-2
Operating the Motor
Step 8
Step 9
Step 10
28
Table 18 Flex Mode Output Area with Typical Configuration
Word offset
+0
Register
Coil data 0
(see note)
dec
0
Value
hex
0000
Bit
Name
Value
Opr
Operation command
Dir
Rotation direction command
EXT
External Trip
RS
Trip reset
In1
Intelligent input terminal [1]
In2
Intelligent input terminal [2]
Table 19 Flex Mode Input Area with Typical Configuration
Word offset
+0
Register
Invstat C
dec
1
Value
hex
0001
Bit
15
Name
ONT RNT TRQ UV
Value
Dir
Rotation direction
Rdy
Inverter ready
RUN
Running
FA1
Constant-speed reached
FA2
Set frequency overreached
OL
Overload advance notice
OD
Output deviation for PID control
Invstat C Inverter status C (Refer to Inverter Manual section B-4-2)
Confirm the Output has a data size of 3 words and the Input has 4 words. This
is because P163 to P169 and P174 to P179 are all set to zero.
Note
Do not set bit 15 of the Coil data 0 to ON. The operation status coil (000Fh)
cannot be used in the output process area.
Set A001 = 3 and A002 = 3 so that the Inverter can be controlled using the
Modbus registers in Flexible mode.
Set the Opr bit to put the Inverter in run mode. The RUN indicator on the
Inverter should light up at this point. If this is not the case, check your source
selection.
Change F001 in the Output data to the desired frequency (E.g. 1000 for
10.00 Hz)
Table 20 Flex Mode Output Area with Motor Running Forward
Word offset
+0
Register
Coil data 0
dec
2
Value
hex
0002
Bit
Name
Value
The motor accelerates until it reaches the desired frequency. Notice that the
FA1 bit is set once the inverter has reached the desired reference frequency.
+1
+2
+3
-
F001 (0001h/0002h)
0
0
0000
0000
0000
15
14
13
12
11
10
9
-
-
In7
In6
In5
In4
In3
In2
0
0
0
0
0
0
0
+1
+2
+3
Coil data 1
d001 (1001h/1002h)
2
0
0002
0000
0000
14
13
12
11
10
9
- OTQ FA3 AL OD OL FA2 FA1 RUN -
0
0
0
0
0
0
0
+1
+2
+3
F001 (0001h/0002h)
-
+1000
0
0000
03E8
0000
15
14
13
12
11
10
9
*1
-
-
In7 In6 In5 In4 In3 In2 In1
0
0
0
0
0
0
0
+4
+5
+6
+7
-
-
-
-
0
0
0
0
0000
0000
0000
0000
8
7
6
5
4
3
2
In1
-
-
RS EXT Dir
Opr
0
0
0
0
0
0
0
In3
Intelligent input terminal [3]
In4
Intelligent input terminal [4]
In5
Intelligent input terminal [5]
In6
Intelligent input terminal [6]
In7
Intelligent input terminal [7]
+4
+5
+6
+7
-
-
-
-
0
0
0
0
0000
0000
0000
0000
8
7
6
5
4
3
2
Rdy Dir
0
0
0
0
0
0
0
AL
Alarm signal
FA3
Set frequency reached
OTQ
Over-torque
UV
Undervoltage
TRQ
Torque limited
RNT
Operation time over
ONT
Plug-in time over
+4
+5
+6
+7
-
-
-
-
0
0
0
0
0000
0000
0000
0000
8
7
6
5
4
3
2
-
-
RS EXT Dir Opr
0
0
0
0
0
0
0
Section 4-7
+8
+9
-
-
0
0
0000
0000
1
0
-
0
0
+8
+9
-
-
0
0
0000
0000
1
0
1
0
+8
+9
-
-
0
0
0000
0000
1
0
-
1
0