Connection Object (Class 0x05)
C-5
Connection Object (Class 0x05)
Supported Service Codes
Object Details
Table C-9 Connection Object - Object Details
Instance
Attribute
(hex)
(hex)
01
01
State
Explicit
02
Instance type
03
TransportClass
_Trigger
04
DeviceNet_Pro
duced_Connec
tion_ID
05
DeviceNet_Co
nsumed_Conn
ection_ID
06
Initial Comm
characteristics
07
Produced con-
nection size
08
Consumed
connection size
09
Expected
packet rate
0C
Watchdog tim-
eout action
0D
Produced con-
nection path
length
0E
Produced con-
nection path
0F
Consumed
connection
path length
10
Consumed
connection
path
11
Production
inhibit time
12
Connection
timeout multi-
plier
Table C-8 Connection Object - Supported Service Codes
Service Code No. (hex)
0E
10
Name
Content
Status of the instance
Type of the instance
Defines behaviour of the connec-
tion
Label indicating communication ID
as set by DeviceNet master Unit.
Label indicating communication ID
as set by DeviceNet master Unit.
Indicates the communication con-
figuration for the DeviceNet master
Unit.
Indicates the maximum number of
bytes for transmission.
Indicates the maximum number of
bytes for reception.
Indicates the length of the internal
processing timeout when a com-
munication request is received
(incremented by 10 ms units)
Indicates the action for internal
processing timeout related to com-
munications.
00: Retain timeout status (until
reset or cleared)
01: Cut connection automatically
02: Operate again with same con-
nection as is
Number of bytes for produced con-
nection path.
No data for explicit messages
Specifies the application object for
produced connection path.
No data for explicit messages
Number of bytes for consumed
connection path.
No data for explicit messages
Specifies the application object for
consumed connection path.
No data for explicit messages
Specifies the production inhibit
timer value.
Specifies the multiplier for the con-
nection timeout event.
Service
Get attribute single
Set attribute single
Setting
Default
range
----
----
----
83 Hex
----
----
----
----
----
21 Hex
----
260
----
260
0 -
65535
----
----
----
Empty
----
----
Empty
----
----
Fixed to 4
APPENDIX C
Get
Set
Size
3
Yes
No
USINT
0
Yes
No
USINT
Yes
No
BYTE
Yes
No
UINT
Yes
No
UINT
Yes
No
BYTE
Yes
No
UINT
Yes
No
UINT
0
Yes
Yes
UINT
1
Yes
Yes
USINT
0
Yes
No
UINT
Yes
No
ARRAY
0
Yes
No
UINT
Yes
No
ARRAY
0
Yes
No
UINT
Yes
No
USINT
59